+This document describes how to deployment IEC platform with Contiv-VPP
+networking on bare metal hosts.The automatic deployment script provided
+by IEC uses calico CNI by default. To enable Contiv-VPP network solution
+for Kubernetes, you need to make some minor modifications.Now the IEC
+only supports multiple NICs deployment, and does not support Configuring
+STN for the time being.In addition, the deployment methods of IEC type1
+and type2 are slightly different, and will be introduced in different
+chapters.
+
+Setting up for IEC type2
+------------------------
+
+IEC type2 deploy on large and powerful business servers.The main
+installation steps as following:
+
+Setting up DPDK
+~~~~~~~~~~~~~~~
+
+ALL port that are to be used by an DPDK aplication must be bound to the
+uio_pci_generic, igb_uio or vfio-pci module before the application is
+run, more detail info please refer `DPDK DOC`_.
+
+The following guide will use vfio-pci. Load kernel module
+
+::
+
+    $ sudo modprobe vfio-pci
+
+Verify that PCI driver has loaded successfully
+
+::
+
+    $ lsmod |grep pci
+    vfio_pci               49152  0
+    vfio_virqfd            16384  1 vfio_pci
+    vfio_iommu_type1       24576  0
+    vfio                   40960  2 vfio_iommu_type1,vfio_pci
+
+Determining network adapter that vpp to use
+
+::
+
+    $ sudo lshw -class network -businfo
+    Bus info          Device       Class      Description
+    ================================================
+    pci@0000:89:00.0  enp137s0f0   network    Ethernet Controller X710 for 10GbE SFP+
+    pci@0000:89:00.1  enp137s0f1   network    Ethernet Controller X710 for 10GbE SFP+
+
+In this example, enp137s0f1 used by vpp and binding to kernel module:
+
+::
+
+    $ sudo ~/dpdk/usertools/dpdk-devbind.py --bind=vfio-pci enp137s0f1
+
+The script dpdk-devbind.py in `DPDK`_ repo.
+
+Automation deployment
+~~~~~~~~~~~~~~~~~~~~~
+
+As a minimum requirement 3 nodes are needed: jumpserver, master node and
+worker node. The two kinds nodes are configured by different script.
+
+-  Modify default network solution
+
+.. code:: diff
+
+    --- a/src/foundation/scripts/config
+    +++ b/src/foundation/scripts/config
+    @@ -30,7 +30,7 @@ K8S_WORKER_GROUP=(
+     CLUSTER_IP=172.16.1.136 # Align with the value in our K8s setup script
+     POD_NETWORK_CIDR=192.168.0.0/16
+     #IEC support three kinds network solution for Kubernetes: calico,flannel,contivpp
+    -CNI_TYPE=calico
+    +CNI_TYPE=contivpp
+     #kubernetes-cni version 0.7.5/ 0.6.0
+     CNI_VERSION=0.6.0
+
+-  Master node configuration
+
+Initialize DEV_NAME for master node,Instantiate the fourth argument of the setup-cni.sh script
+
+.. code:: diff
+
+    --- a/src/foundation/scripts/startup.sh
+    +++ b/src/foundation/scripts/startup.sh
+    @@ -99,7 +99,7 @@ deploy_k8s () {
+       #Deploy etcd & CNI from master node
+    -  SETUP_CNI="cd iec/src/foundation/scripts && source setup-cni.sh $CLUSTER_IP $POD_NETWORK_CIDR $CNI_TYPE"
+    +  SETUP_CNI="cd iec/src/foundation/scripts && source setup-cni.sh $CLUSTER_IP $POD_NETWORK_CIDR $CNI_TYPE enp137s0f1"
+       sshpass -p ${K8S_MASTERPW} ssh -o StrictHostKeyChecking=no ${HOST_USER}@${K8S_MASTER_IP} ${SETUP_CNI}
+       SETUP_HELM="cd iec/src/foundation/scripts && source helm.sh"
+
+The modified result is as follows
+
+.. code:: diff
+
+    --- a/src/foundation/scripts/setup-cni.sh
+    +++ b/src/foundation/scripts/setup-cni.sh
+    @@ -11,7 +11,7 @@ fi
+     CLUSTER_IP=${1:-172.16.1.136} # Align with the value in our K8s setup script
+     POD_NETWORK_CIDR=${2:-192.168.0.0/16}
+     CNI_TYPE=${3:-calico}
+    -DEV_NAME=${4:-}
+    +DEV_NAME=${4:-enp137s0f1}
+
+-  Worker node configuration
+
+The same as master node, worker node need setting up DPDK and
+determining network adapter. Initialize DEV_NAME for work node
+
+.. code:: diff
+
+    --- a/src/foundation/scripts/config
+    +++ b/src/foundation/scripts/config
+    @@ -42,4 +42,4 @@ KUBE_VERSION=1.13.0
+     #  [10.169.40.106]="enp137s0f0"
+     #  )
+     declare -A DEV_NAME
+    -DEV_NAME=()
+    +DEV_NAME=([10.169.40.106]="enp137s0f0")
+
+DEV_NAME is an associative array, list network interface device names
+used by contivpp. Use IP address of K8S_WORKER_GROUP as key.
+
+-  Launch setup
+
+Simply start the installation script startup.sh on jumpserver:
+
+::
+
+    jenkins@jumpserver:~/iec/src/foundation/scripts$ ./startup.sh
+
+for more details and information refer to `installation.instruction.rst`_
+
+Setting up for IEC type1
+------------------------
+
+IEC type1 device is suitable for low power device.Now we choose
+`MACCHIATObin`_ board as the main hardware
+platform.
+
+Install MUSDK
+~~~~~~~~~~~~~
+
+Marvell User-Space SDK(`MUSDK`_)
+is a light-weight user-space I/O driver for Marvell's Embedded
+Networking SoC's, more detail info please refer `VPP Marvell plugin`_
+
+Automation deployment
+~~~~~~~~~~~~~~~~~~~~~
+
+-  Modify default yaml
+
+.. code:: diff
+
+    diff --git a/src/foundation/scripts/setup-cni.sh b/src/foundation/scripts/setup-cni.sh
+    index d466831..6993006 100755
+    --- a/src/foundation/scripts/setup-cni.sh
+    +++ b/src/foundation/scripts/setup-cni.sh
+    @@ -43,7 +43,7 @@ install_contivpp(){
+
+       # Install contivpp CNI
+       sed -i "s@10.1.0.0/16@${POD_NETWORK_CIDR}@" "${SCRIPTS_DIR}/cni/contivpp/contiv-vpp.yaml"
+    -  kubectl apply -f "${SCRIPTS_DIR}/cni/contivpp/contiv-vpp.yaml"
+    +  kubectl apply -f "${SCRIPTS_DIR}/cni/contivpp/contiv-vpp-macbin.yaml"
+     }
+
+-  Configuration
+
+To configure a PP2 interface, MainVppInterface with the prefix mv-ppio-
+must be configured in the NodeConfig section of the deployment yaml.
+mv-ppio-X/Y is VPP interface name where X is PP2 device ID and Y is PPIO
+ID Interface needs to be assigned to MUSDK in FDT configuration and
+linux interface state must be up. Example configuration:
+
+::
+
+    ~/iec/src/foundation/scripts/cni/contivpp/contiv-vpp-macbin.yaml
+        nodeConfig:
+        - nodeName: net-arm-mcbin-iec
+          mainVppInterface:
+            interfaceName: mv-ppio-0/0
+        - nodeName: net-arm-mcbin-iec-1
+          mainVppInterface:
+            interfaceName: mv-ppio-0/0
+
+PP2 doesn't have any dependency on DPDK or DPDK plugin but it can work
+with DPDK plugin enabled or disabled.It is observed that performace is
+better around 30% when DPDK plugin is disabled. DPKD plugin can be
+disabled by adding following config to the contiv-vswitch.conf.
+
+.. code:: diff
+
+    --- a/src/foundation/scripts/cni/contivpp/contiv-vswitch.conf
+    +++ b/src/foundation/scripts/cni/contivpp/contiv-vswitch.conf
+    @@ -24,3 +24,7 @@ socksvr {
+     statseg {
+        default
+     }
+    +plugins {
+    +        plugin vpp_plugin.so { enable }
+    +        plugin dpdk_plugin.so { disable }
+    +}
+
+-  Modify scripts
+
+It`s necessary to modify relevant script as IEC type2 to support automatic deployment.
+
+-  Launch setup
+
+Simply start the installation script startup.sh on jumpserver:
+
+::
+
+    jenkins@jumpserver:~/iec/src/foundation/scripts$ ./startup.sh
+
+for more details and information refer to
+`installation.instruction.rst`_
+
+Deployment Verification
+-----------------------
+
+invok ./src/foundation/scripts/nginx.sh install nginx; to test if CNI
+enviroment is ready.
+
+Uninstalling Contiv-VPP
+-----------------------
+
+To uninstall the network plugin for type2:
+
+::
+
+    kubectl delete -f  ./iec/src/foundation/scripts/cni/contivpp/contiv-vpp.yaml
+
+To uninstall the network plugin for type1:
+
+::
+
+    kubectl delete -f  ./iec/src/foundation/scripts/cni/contivpp/contiv-vpp-macbin.yaml
+
+In order to remove the persisted config, cleanup the bolt and ETCD
+storage:
+
+::
+
+    rm -rf /var/etcd/contiv-data
+
+.. All links go below this line
+.. _`DPDK DOC`: https://doc.dpdk.org/guides/linux_gsg/linux_drivers.html#binding-and-unbinding-network-ports-to-from-the-kernel-modules
+.. _`DPDK`: https://github.com/DPDK/dpdk/blob/master/usertools/dpdk-devbind.py
+.. _`installation.instruction.rst`: ./installation.instruction.rst
+.. _`MACCHIATObin`: http://macchiatobin.net
+.. _`MUSDK`: https://github.com/MarvellEmbeddedProcessors/musdk-marvell
+.. _`VPP Marvell plugin`: https://github.com/FDio/vpp/blob/master/src/plugins/marvell/README.md