Deleting old ovsdpdk site type of R1 release
[yaml_builds.git] / site_type / ovsdpdk / airship-treasuremap / site / airship-seaworthy / baremetal / nodes.yaml
diff --git a/site_type/ovsdpdk/airship-treasuremap/site/airship-seaworthy/baremetal/nodes.yaml b/site_type/ovsdpdk/airship-treasuremap/site/airship-seaworthy/baremetal/nodes.yaml
deleted file mode 100644 (file)
index ee88a16..0000000
+++ /dev/null
@@ -1,254 +0,0 @@
----
-# Drydock BaremetalNode resources for a specific rack are stored in this file.
-#
-# NOTE: For new sites, you should complete the networks/physical/networks.yaml
-# file before working on this file.
-#
-# In this file, you should make the number of `drydock/BaremetalNode/v1`
-# resources equal the number of bare metal nodes you have, either by deleting
-# excess BaremetalNode definitions (if there are too many), or by copying and
-# pasting the last BaremetalNode in the file until you have the correct number
-# of baremetal nodes (if there are too few).
-#
-# Then in each file, address all additional NEWSITE-CHANGEME markers to update
-# the data in these files with the right values for your new site.
-#
-# *NOTE: The Genesis node is counted as one of the control plane nodes. Note
-# that the Genesis node does not appear on this bare metal list, because the
-# procedure to reprovision the Genesis host with MaaS has not yet been
-# implemented. Therefore there will be only three bare metal nodes in this file
-# with the 'masters' tag, as the genesis roles are assigned in a difference
-# place (profiles/genesis.yaml).
-# NOTE: The host profiles for the control plane are further divided into two
-# variants: primary and secondary. The only significance this has is that the
-# "primary" nodes are active Ceph nodes, whereas the "secondary" nodes are Ceph
-# standby nodes. For Ceph quorum, this means that the control plane split will
-# be 3 primary + 1 standby host profile, and the Genesis node counts toward one
-# of the 3 primary profiles. Other control plane services are not affected by
-# primary vs secondary designation.
-#
-# TODO: Include the hostname naming convention
-#
-schema: 'drydock/BaremetalNode/v1'
-metadata:
-  schema: 'metadata/Document/v1'
-  # NEWSITE-CHANGEME: Replace with the hostname of the first node in the rack,
-  # after (excluding) genesis.
-  name: cab23-r720-12
-  layeringDefinition:
-    abstract: false
-    layer: site
-  storagePolicy: cleartext
-data:
-  # NEWSITE-CHANGEME: The IPv4 address assigned to each logical network on this
-  # node. In the reference Airship deployment, this is all logical Networks defined
-  # in networks/physical/networks.yaml. IP addresses are manually assigned, by-hand.
-  # (what could possibly go wrong!) The instructions differ for each logical
-  # network, which are laid out below.
-  addressing:
-    # The iDrac/iLo IP of the node. It's important that this match up with the
-    # node's hostname above, so that the rack number and node position encoded
-    # in the hostname are accurate and matching the node that IPMI operations
-    # will be performed against (for poweron, poweroff, PXE boot to wipe disk or
-    # reconfigure identity, etc - very important to get right for these reasons).
-    # These addresses should already be assigned to nodes racked and stacked in
-    # the environment; these are not addresses which MaaS assigns.
-    - network: oob
-      address: 10.23.104.12
-    # The IP of the node on the PXE network. Refer to the static IP range
-    # defined for the PXE network in networks/physical/networks.yaml. Begin allocating
-    # IPs from this network, starting with the second IP (inclusive) from the
-    # allocation range of this subnet (Genesis node will have the first IP).
-    # Ex: If the start IP for the PXE "static" network is 10.23.20.11, then
-    # genesis will have 10.23.20.11, this node will have 10.23.20.12, and
-    # so on with incrementing IP addresses with each additional node.
-    - network: pxe
-      address: 10.23.20.12
-    # Genesis node gets first IP, all other nodes increment IPs from there
-    # within the allocation range defined for the network in
-    # networks/physical/networks.yaml
-    - network: oam
-      address: 10.23.21.12
-    # Genesis node gets first IP, all other nodes increment IPs from there
-    # within the allocation range defined for the network in
-    # networks/physical/networks.yaml
-    - network: storage
-      address: 10.23.23.12
-    # Genesis node gets first IP, all other nodes increment IPs from there
-    # within the allocation range defined for the network in
-    # networks/physical/networks.yaml
-    - network: overlay
-      address: 10.23.24.12
-    # Genesis node gets first IP, all other nodes increment IPs from there
-    # within the allocation range defined for the network in
-    # networks/physical/networks.yaml
-    - network: calico
-      address: 10.23.22.12
-  # NEWSITE-CHANGEME: Set the host profile for the node.
-  # Note that there are different host profiles depending if this is a control
-  # plane vs data plane node, and different profiles that map to different types
-  # hardware. Control plane host profiles are further broken down into "primary"
-  # and "secondary" profiles (refer to the Notes section at the top of this doc).
-  # Select the host profile that matches up to your type of
-  # hardware and function. E.g., the r720 here refers to Dell R720 hardware, the
-  # 'cp' refers to a control plane profile, and the "primary" means it will be
-  # an active member in the ceph quorum. Refer to profiles/host/ for the list
-  # of available host profiles specific to this site (otherwise, you may find
-  # a general set of host profiles at the "type" or "global" layers/folders.
-  # If you have hardware that is not on this list of profiles, you may need to
-  # create a new host profile for that hardware.
-  # Regarding control plane vs other data plane profiles, refer to the notes at
-  # the beginning of this file. There should be one control plane node per rack,
-  # including Genesis. Note Genesis won't actually be listed in this file as a
-  # BaremetalNode, but the rest are.
-  # This is the second "primary" control plane node after Genesis.
-  host_profile: cp_r720-primary
-  metadata:
-    tags:
-      # NEWSITE-CHANGEME: See previous comment. Apply 'masters' tag for control
-      # plane node, and 'workers' tag for data plane hosts.
-      - 'masters'
-    # NEWSITE-CHANGEME: Refer to site engineering package or other supporting
-    # documentation for the specific rack name. This should be a rack name that
-    # is meaningful to data center personnel (i.e. a rack they could locate if
-    # you gave them this rack designation).
-    rack: cab23
-...
----
-schema: 'drydock/BaremetalNode/v1'
-metadata:
-  schema: 'metadata/Document/v1'
-  # NEWSITE-CHANGEME: The next node's hostname
-  name: cab23-r720-13
-  layeringDefinition:
-    abstract: false
-    layer: site
-  storagePolicy: cleartext
-data:
-  # NEWSITE-CHANGEME: The next node's IPv4 addressing
-  addressing:
-    - network: oob
-      address: 10.23.104.13
-    - network: pxe
-      address: 10.23.20.13
-    - network: oam
-      address: 10.23.21.13
-    - network: storage
-      address: 10.23.23.13
-    - network: overlay
-      address: 10.23.24.13
-    - network: calico
-      address: 10.23.22.13
-  # NEWSITE-CHANGEME: The next node's host profile
-  host_profile: cp_r720-primary
-  metadata:
-    # NEWSITE-CHANGEME: The next node's rack designation
-    rack: cab23
-    # NEWSITE-CHANGEME: The next node's role desigatnion
-    tags:
-      - 'masters'
-...
----
-schema: 'drydock/BaremetalNode/v1'
-metadata:
-  schema: 'metadata/Document/v1'
-  # NEWSITE-CHANGEME: The next node's hostname
-  name: cab23-r720-14
-  layeringDefinition:
-    abstract: false
-    layer: site
-  storagePolicy: cleartext
-data:
-  # NEWSITE-CHANGEME: The next node's IPv4 addressing
-  addressing:
-    - network: oob
-      address: 10.23.104.14
-    - network: pxe
-      address: 10.23.20.14
-    - network: oam
-      address: 10.23.21.14
-    - network: storage
-      address: 10.23.23.14
-    - network: overlay
-      address: 10.23.24.14
-    - network: calico
-      address: 10.23.22.14
-  # NEWSITE-CHANGEME: The next node's host profile
-  # This is the third "primary" control plane profile after genesis
-  host_profile: cp_r740-secondary
-  metadata:
-    # NEWSITE-CHANGEME: The next node's rack designation
-    rack: cab23
-    # NEWSITE-CHANGEME: The next node's role desigatnion
-    tags:
-      - 'masters'
-...
----
-schema: 'drydock/BaremetalNode/v1'
-metadata:
-  schema: 'metadata/Document/v1'
-  # NEWSITE-CHANGEME: The next node's hostname
-  name: cab23-r720-17
-  layeringDefinition:
-    abstract: false
-    layer: site
-  storagePolicy: cleartext
-data:
-  # NEWSITE-CHANGEME: The next node's IPv4 addressing
-  addressing:
-    - network: oob
-      address: 10.23.104.17
-    - network: pxe
-      address: 10.23.20.17
-    - network: oam
-      address: 10.23.21.17
-    - network: storage
-      address: 10.23.23.17
-    - network: overlay
-      address: 10.23.24.17
-    - network: calico
-      address: 10.23.22.17
-  # NEWSITE-CHANGEME: The next node's host profile
-  # This is the one and only appearance of the "secondary" control plane profile
-  host_profile: dp_r720
-  metadata:
-    # NEWSITE-CHANGEME: The next node's rack designation
-    rack: cab23
-    # NEWSITE-CHANGEME: The next node's role desigatnion
-    tags:
-      - 'workers'
-...
----
-schema: 'drydock/BaremetalNode/v1'
-metadata:
-  schema: 'metadata/Document/v1'
-  # NEWSITE-CHANGEME: The next node's hostname
-  name: cab23-r720-19
-  layeringDefinition:
-    abstract: false
-    layer: site
-  storagePolicy: cleartext
-data:
-  # NEWSITE-CHANGEME: The next node's IPv4 addressing
-  addressing:
-    - network: oob
-      address: 10.23.104.19
-    - network: pxe
-      address: 10.23.20.19
-    - network: oam
-      address: 10.23.21.19
-    - network: storage
-      address: 10.23.23.19
-    - network: overlay
-      address: 10.23.24.19
-    - network: calico
-      address: 10.23.22.19
-  # NEWSITE-CHANGEME: The next node's host profile
-  host_profile: dp_r720
-  metadata:
-    # NEWSITE-CHANGEME: The next node's rack designation
-    rack: cab23
-    # NEWSITE-CHANGEME: The next node's role desigatnion
-    tags:
-      - 'workers'
-...