Fix: First boot from floppy, not CD-ROM 00/3800/1 master
authordave kormann <davek@research.att.com>
Mon, 19 Oct 2020 20:20:42 +0000 (16:20 -0400)
committerdave kormann <davek@research.att.com>
Mon, 19 Oct 2020 20:23:09 +0000 (16:23 -0400)
The remote installer sets the next boot to the floppy device, apparently
to force a boot from remote media.  On current OE19 firmware, this
appears to result in a boot from the default hard drive instead.  This
change sets the next boot to cd, which appears to work when issued
manually

signed-off-by: dave kormann    <davek@research.att.com>
Change-Id: Ib44550055596cf69a688b0e57060d8315cb6e887

src/remoteinstaller/installer/bmc_management/oe19.py

index dc44d99..eafd594 100644 (file)
@@ -20,5 +20,5 @@ class OE19(OR18):
         super(OE19, self).__init__(host, user, passwd, priv_level, log_path)
 
     def _set_boot_from_virtual_media(self):
         super(OE19, self).__init__(host, user, passwd, priv_level, log_path)
 
     def _set_boot_from_virtual_media(self):
-        logging.debug('Set boot from floppy (%s), and boot after that', self._host)
-        self._run_ipmitool_command('chassis bootdev floppy options=persistent')
+        logging.debug('Set boot from cdrom (%s), and boot after that', self._host)
+        self._run_ipmitool_command('chassis bootdev cdrom options=persistent')